Traceback (most recent call last):
File "<input>", line 2, in <module>
File "/home/test/projects/venv/lib/python3.6/site-packages/MySQLdb/__init__.py", line 85, in Connect
return Connection(*args, **kwargs)
File "/home/test/projects/venv/lib/python3.6/site-packages/MySQLdb/connections.py", line 208, in __init__
super(Connection, self).__init__(*args, **kwargs2)
TypeError: connect() argument 12 must be str, not PosixPath
Activity
fried commentedon Mar 23, 2019
Only after Python 3.6 but you can use
os.fsencode(bytes/str/Path) -> bytes
Would have to do it in connections.py